Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Vaccine ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38631952

RESUMEN

The U.S. COVID-19 vaccination program, which commenced in December 2020, has been instrumental in preventing morbidity and mortality from COVID-19 disease. Safety monitoring has been an essential component of the program. The federal government undertook a comprehensive and coordinated approach to implement complementary safety monitoring systems and to communicate findings in a timely and transparent way to healthcare providers, policymakers, and the public. Monitoring involved both well-established and newly developed systems that relied on both spontaneous (passive) and active surveillance methods. Clinical consultation for individual cases of adverse events following vaccination was performed, and monitoring of special populations, such as pregnant persons, was conducted. This report describes the U.S. government's COVID-19 vaccine safety monitoring systems and programs used by the Centers for Disease Control and Prevention, the U.S. Food and Drug Administration, the Department of Defense, the Department of Veterans Affairs, and the Indian Health Service. Using the adverse event of myocarditis following mRNA COVID-19 vaccination as a model, we demonstrate how the multiple, complementary monitoring systems worked to rapidly detect, assess, and verify a vaccine safety signal. In addition, longer-term follow-up was conducted to evaluate the recovery status of myocarditis cases following vaccination. Finally, the process for timely and transparent communication and dissemination of COVID-19 vaccine safety data is described, highlighting the responsiveness and robustness of the U.S. vaccine safety monitoring infrastructure during the national COVID-19 vaccination program.

2.
J Am Heart Assoc ; 13(6): e031029, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38471835

RESUMEN

BACKGROUND: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. METHODS AND RESULTS: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein-10, angiopoietin-2, fibroblast growth factor-23, insulin-like growth factor-binding protein-7, myosin-binding protein C3, growth differentiation factor-15, interleukin-6, N-terminal pro-brain natriuretic peptide, and high-sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [<60 ml/min/1.73m2], LA diameter ≥43 mm, EF <50%; which includes age, left atrial diameter, left ventricular ejection fraction, persistent atrial fibrillation, and estimated glomerular filtration rate), preablation rhythm, sex, height, body mass index, presence of an implanted continuous monitor, year of ablation, and additional linear ablation. A total of 1873 participants were included. A multivariable logistic regression showed an association between recurrence and levels of angiopoietin-2 (odds ratio, 1.08 [95% CI, 1.02-1.15], P=0.007) and interleukin-6 (odds ratio, 1.02 [95% CI, 1.003-1.03]; P=0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. CONCLUSIONS: Higher angiopoietin-2 and interleukin-6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Humanos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Angiopoyetina 2 , Interleucina-6 , Modelos Estadísticos , Volumen Sistólico , Remodelación Ventricular , Factores de Riesgo , Pronóstico , Recurrencia , Función Ventricular Izquierda , Biomarcadores , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
3.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38367008

RESUMEN

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Taquicardia Ventricular , Masculino , Humanos , Persona de Mediana Edad , Femenino , Solución Salina/efectos adversos , Vapor , Estudios Prospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Taquicardia Ventricular/cirugía , Irrigación Terapéutica/efectos adversos
4.
N Engl J Med ; 390(3): 269-270, 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38231629
5.
JACC Clin Electrophysiol ; 10(2): 193-202, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38069975

RESUMEN

BACKGROUND: Risks of radiofrequency catheter ablation for ventricular arrhythmias include emboli and bleeding complications but data on antithrombotic regimens are limited and guidelines do not specify a systematic approach. OBJECTIVES: This study sought to assess embolic and bleeding complications in relation to pre-periprocedure and post-periprocedure antithrombotic regimens. METHODS: Prospective assessment for complications was performed for 663 endocardial radiofrequency catheter ablation procedures in 616 consecutive patients (median age 64 years [Q1-Q3: 54-73 years], 70.3% men, 71.6% with cardiomyopathy, 44.5% with sustained ventricular tachycardia). RESULTS: There were 2 strokes (0.3%; 95% CI: 0.0%-0.8%), 1 transient ischemic attack (0.15%), and 2 pulmonary emboli (0.3%). There were 39 bleeding complications (5.9%) including 11 pericardial effusions (1.7%), and 28 related to vascular access (4.2%). Consistent with the prevalence of coronary artery disease (47.5%), atrial fibrillation (30.0%), and prior stroke (10.6%), preprocedure, 464 patients (70.0%) were taking antithrombotic agents including 220 (33.2%) taking aspirin alone (ASA), and 163 (24.6%) taking warfarin or a direct acting oral anticoagulant (DOAC). Preprocedure non-ASA antiplatelet use (OR: 2.846; P = 0.011) and DOAC use (OR: 2.585; P = 0.032) were associated with risk of bleeding complications. Following ablation, 49.8% of patients were treated with ASA 325 mg/d and 30.3% received DOACs or warfarin. New DOAC or warfarin administration was initiated in only 6.6% of patients. Overall, 39.7% of patients continued the same preprocedure antithrombotic regimen. CONCLUSIONS: Stroke is a rare complication of radiofrequency catheter ablation for ventricular arrhythmia using ASA 325 mg/d as a minimal postprocedure regimen with more potent regimens for selected patients.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Masculino , Humanos , Persona de Mediana Edad , Femenino , Warfarina/efectos adversos , Anticoagulantes/efectos adversos , Hemorragia/etiología , Hemorragia/inducido químicamente , Fibrinolíticos , Estudios Prospectivos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/epidemiología , Fibrilación Atrial/cirugía , Aspirina/efectos adversos
6.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1147-1157, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37495323

RESUMEN

BACKGROUND: Experimental evidence suggests genetic variation in 4q25/PITX2 modulates pulmonary vein (PV) myocardial sleeve length. Although PV sleeves are the main target of atrial fibrillation (AF) ablation, little is known about the association between different PV sleeve characteristics with ablation outcomes. OBJECTIVES: This study sought to evaluate the association between clinical and genetic (4q25) risk factors with PV sleeve length in humans, and to evaluate the association between PV sleeve length and recurrence after AF ablation. METHODS: In a prospective, observational study of patients undergoing de novo AF ablation, PV sleeve length was measured using electroanatomic voltage mapping before ablation. The sentinel 4q25 AF susceptibility single nucleotide polymorphism, rs2200733, was genotyped. The primary analysis tested the association between clinical and genetic (4q25) risk factors with PV sleeve length using a multivariable linear regression model. Covariates included age, sex, body mass index, height, and persistent AF. The association between PV sleeve length and atrial arrhythmia recurrence (>30 seconds) was tested using a multivariable Cox proportional hazards model. RESULTS: Between 2014 and 2019, 197 participants were enrolled (median age 63 years [IQR: 55 to 70 years], 133 male [67.5%]). In multivariable modeling, men were found to have PV sleeves 2.94 mm longer than women (95% CI: 0.99-4.90 mm; P < 0.001). Sixty participants (30.5%) had one 4q25 risk allele and 6 (3.1%) had 2 alleles. There was no association between 4q25 genotype and PV sleeve length. Forty-six participants (23.4%) experienced arrhythmia recurrence within 3 to 12 months, but there was no association between recurrence and PV sleeve length. CONCLUSIONS: Common genetic variation at 4q25 was not associated with PV sleeve length and PV sleeve length was not associated with ablation outcomes. Men did have longer PV sleeves than women, but more research is needed to define the potential clinical significance of this observation.


Asunto(s)
Fibrilación Atrial , Venas Pulmonares , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/genética , Fibrilación Atrial/cirugía , Genotipo , Estudios Prospectivos , Venas Pulmonares/cirugía , Factores de Riesgo , Anciano , Proteína del Homeodomínio PITX2
7.
PLoS One ; 18(5): e0283988, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37155666

RESUMEN

OBJECTIVES: (1) Characterize the initial clinical characteristics and long-term outcomes of smallpox vaccine-associated hypersensitivity myocarditis and pericarditis (MP) in United States service members. (2) Describe the process of case identification and adjudication using the 2003 CDC nationally defined myocarditis/pericarditis epidemiologic case definitions to include consideration of case-specific diversity and evolving evidence. BACKGROUND: Between 2002 and 2016, 2.546 million service members received a smallpox Vaccinia vaccine. Acute MP is associated with vaccinia, but the long-term outcomes have not been studied. METHODS: Records of vaccinia-associated MP reported to the Vaccine Adverse Event Reporting System by vaccination date were adjudicated using the 2003 MP epidemiologic case definitions for inclusion in a retrospective observational cohort study. Descriptive statistics of clinical characteristics, presentation, cardiac complications, and time course of clinical and cardiac recovery were calculated with comparisons by gender, diagnosis and time to recovery. RESULTS: Out of over 5000 adverse event reports, 348 MP cases who survived the acute illness, including 276 myocarditis (99.6% probable/confirmed) and 72 pericarditis (29.2% probable/confirmed), were adjudicated for inclusion in the long-term follow-up. Demographics included a median age of 24 years (IQR 21,30) and male predominance (96%). Compared to background military population, the myocarditis and pericarditis cohort had a higher percentage of white males by 8.2% (95% CI: 5.6, 10.0) and age <40 years by 4.2% (95% CI: 1.7,5.8). Long-term follow-up documented full recovery in 267/306 (87.3%) with 74.9% recovered in less than a year (median ~3 months). Among patients with myocarditis, the percentage who had a delayed time to recovery at time of last follow-up was 12.8% (95% CI: 2.1,24.7) higher in those with an acute left ventricular ejection fraction (EF) of ≤50% and 13.5% (95% CI: 2.4,25.7) higher in those with hypokinesis. Patient complications included 6 ventricular arrhythmias (2 received implanted defibrillators) and 14 with atrial arrhythmias (2 received radiofrequency ablation). Three of 6 patients (50%) diagnosed with cardiomyopathy had clinical recovery at their last follow-up date. CONCLUSIONS: Hypersensitivity myocarditis/pericarditis following the smallpox vaccine is associated with full clinical and functional ventricular recovery in over 87% of cases (74.9% <1 year). A minority of MP cases experienced prolonged or incomplete recovery beyond 1 year.


Asunto(s)
Servicios de Salud Militares , Miocarditis , Pericarditis , Vacuna contra Viruela , Viruela , Vaccinia , Humanos , Masculino , Estados Unidos , Adulto , Femenino , Vacuna contra Viruela/efectos adversos , Miocarditis/epidemiología , Miocarditis/etiología , Miocarditis/diagnóstico , Vaccinia/prevención & control , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Vacunación , Pericarditis/epidemiología , Pericarditis/etiología , Pericarditis/diagnóstico , Viruela/prevención & control , Virus Vaccinia
8.
Fed Pract ; 40(1): 6-10, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37223238

RESUMEN

Background: Limited information exists to guide shared clinical decision making on COVID-19 vaccination in persons with a prior history of vaccine-associated myocarditis, pericarditis, or myopericarditis (VAMP). The objective of this retrospective observational case series was to characterize cardiac outcomes within 30 days following receipt of 1 or more COVID-19 vaccinations during 2021 in US service members diagnosed with prior non-COVID-19 VAMP between 1998 and 2019. Methods: As part of the collaborative public health mission with the Centers for Disease Control and Prevention for enhanced vaccine adverse events surveillance, the Defense Health Agency Immunization Healthcare Division maintains a clinical database of service members and beneficiaries referred for suspected adverse events following immunizations. Cases in this database recorded between January 1, 2003, and February 28, 2022, were reviewed to identify individuals with prior VAMP who received a COVID-19 vaccine in 2021 and developed signs or symptoms suggestive of VAMP within 30 days following COVID-19 vaccination. Results: Before the COVID-19 pandemic, 431 service members had verified VAMP. Among these 431 patients, 179 had records that confirmed receipt of a COVID-19 vaccine in 2021. Of these 179 patients, 171 (95.5%) were male. Their median age was 39 years (range, 21-67) at the time of COVID-19 vaccination. Most (n = 172; 96.1%) experienced their original VAMP episode after receipt of the live replicating smallpox vaccine. Eleven patients experienced cardiac-suggestive symptoms (chest pain, palpitations, or dyspnea) within 30 days of COVID-19 vaccination. Four patients met the criteria for recurrent VAMP. Three men aged 49, 50, and 55 years developed myocarditis within 3 days of an mRNA COVID-19 vaccine. One 25-year-old man developed pericarditis within 4 days of receiving an mRNA vaccine. All 4 COVID-19 recurrent VAMP cases fully recovered with minimal supportive care within weeks (myocarditis) to months (pericarditis). Conclusions: As demonstrated by this case series, albeit rare, VAMP may reoccur after COVID-19 vaccination among patients who experienced cardiac injury after smallpox vaccination. The clinical characteristics and course of the 4 recurring cases were mild, appearing similar to the post-COVID-19 VAMP described in individuals without a history of VAMP. More research is warranted on factors that may predispose patients to vaccine-associated cardiac injury and which vaccine platforms or schedules may reduce the risk of recurrence among patients who have experienced these events.

9.
ASAIO J ; 69(8): 782-788, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37084328

RESUMEN

Infection remains a common cause of morbidity and mortality in patients with both left ventricular assist devices (LVADs) and cardiac implanted electronic devices (CIEDs) with limited data describing outcomes in patients who have both devices implanted. We performed a single-center, retrospective, observational cohort study of patients with both a transvenous CIED and LVAD who developed bacteremia. Ninety-one patients were evaluated. Eighty-one patients (89.0%) were treated medically and nine patients (9.9%) underwent surgical management. A multivariable logistic regression showed that blood culture positivity for >72 hours was associated with inpatient death, when controlled for age and management strategy (odds ratio [OR] = 3.73 [95% confidence interval {CI} = 1.34-10.4], p = 0.012). In patients who survived the initial hospitalization, the use of long-term suppressive antibiotics was not associated with the composite outcome of death or infection recurrence within 1 year, when controlled for age and management strategy (OR = 2.31 [95% CI = 0.88-2.62], p = 0.09). A Cox proportional hazards model showed that blood culture positivity for >72 hours was associated with a trend toward increased mortality in the first year, when controlled for age, management strategy, and staphylococcal infection (hazard ratio = 1.72 [95% CI = 0.88-3.37], p = 0.11). Surgical management was associated with a trend toward decreased mortality (hazard ratio = 0.23 [95% CI = 0.05-1.00], p = 0.05).


Asunto(s)
Bacteriemia , Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Estudios Retrospectivos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Estudios de Cohortes , Bacteriemia/etiología , Resultado del Tratamiento
10.
Pacing Clin Electrophysiol ; 46(2): 100-107, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36355425

RESUMEN

BACKGROUND: The subcutaneous ICD (S-ICD) is a viable alternative to transvenous ICD and avoids intravascular complications in patients without a pacing indication. The outcomes of S-ICD implantation are uncertain in patients with prior sternotomy. OBJECTIVE: We aim to compare the implant techniques and outcomes with S-ICD implantation in patients with and without prior sternotomy. METHODS: Multicenter retrospective cohort study including adult patients with an S-ICD implanted between January 2014 and June 2020. Outcomes were compared between patients with and without prior sternotomy. RESULTS: Among the 212 patients (49 ± 15 years old, 43% women, BMI 30 ± 8 kg/m2 , 68% primary prevention, 30% ischemic cardiomyopathy, LVEF median 30% IQR 25%-45%) who underwent S-ICD implantation, 47 (22%) had a prior sternotomy. There was no difference in the sensing vector (57% vs. 53% primary, p = 0.55), laterality of the S-ICD lead to the sternum (94% vs. 96% leftward, p = 0.54), or the defibrillation threshold (65 ± 1.4 J vs. 65 ± 0.8 J, p = 0.76) with versus without prior sternotomy. The frequency of 30-day complications was similar with and without prior sternotomy (n = 3/47 vs. n = 15/165, 6% vs. 9%, p = 0.56). Over a median follow-up of 28 months (IQR 10-49 months), the frequency of inappropriate shocks was similar between those with and without prior sternotomy (n = 3/47 and n = 16/165, 6% vs. 10%, p = 0.58). CONCLUSION: Implantation of an S-ICD in patients with prior sternotomy is safe with a similar risk of 30-day complications and inappropriate ICD shocks as patients without prior sternotomy.


Asunto(s)
Desfibriladores Implantables , Esternotomía , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Esternotomía/efectos adversos , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/etiología
11.
Circ Arrhythm Electrophysiol ; 15(10): e010713, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36166682

RESUMEN

BACKGROUND: Experimental data suggest ryanodine receptor-mediated intracellular calcium leak is a mechanism for atrial fibrillation (AF), but evidence in humans is still needed. Propafenone is composed of two enantiomers that are equally potent sodium-channel blockers; however, (R)-propafenone is an ryanodine receptor inhibitor whereas (S)-propafenone is not. This study tested the hypothesis that ryanodine receptor inhibition with (R)-propafenone prevents induction of AF compared to (S)-propafenone or placebo in patients referred for AF ablation. METHODS: Participants were randomized 4:4:1 to a one-time intravenous dose of (R)-propafenone, (S)-propafenone, or placebo. The study drug was given at the start of the procedure and an AF induction protocol using rapid atrial pacing was performed before ablation. The primary endpoint was 30 s of AF or atrial flutter. RESULTS: A total of 193 participants were enrolled and 165 (85%) completed the study protocol (median age: 63 years, 58% male, 95% paroxysmal AF). Sustained AF and/or atrial flutter was induced in 60 participants (84.5%) receiving (R)-propafenone, 60 (80.0%) receiving (S)-propafenone group, and 12 (63.2%) receiving placebo. Atrial flutter occurred significantly more often in the (R)-propafenone (N=23, 32.4%) and (S)-propafenone (N=26, 34.7%) groups compared to placebo (N=1, 5.3%, P=0.029). There was no significant difference between (R)-propafenone and (S)-propafenone for the primary outcome of AF and/or atrial flutter induction in univariable (P=0.522) or multivariable analysis (P=0.199, adjusted for age and serum drug level). CONCLUSIONS: There is no difference in AF inducibility between (R)-propafenone and (S)-propafenone at clinically relevant concentrations. These results are confounded by a high rate of inducible atrial flutter due to sodium-channel blockade. REGISTRATION: https://clinicaltrials.gov; Unique Identifier: NCT02710669.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Humanos , Masculino , Persona de Mediana Edad , Femenino , Propafenona/efectos adversos , Canal Liberador de Calcio Receptor de Rianodina , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/prevención & control , Fibrilación Atrial/tratamiento farmacológico , Aleteo Atrial/diagnóstico , Aleteo Atrial/prevención & control , Calcio/metabolismo , Sodio , Antiarrítmicos/uso terapéutico
12.
J Cardiovasc Electrophysiol ; 33(8): 1655-1664, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35598280

RESUMEN

INTRODUCTION: To target posterior wall isolation (PWI) in atrial fibrillation (AF) ablation, diffuse ablation theoretically confers a lower risk of conduction recovery compared to box set. We sought to assess the safety and efficacy of diffuse PWI with low-flow, medium-power, and short-duration (LF-MPSD) ablation, and evaluate the durability of pulmonary vein isolation (PVI) and PWI among patients undergoing repeat ablations. METHODS: We retrospectively studied patients undergoing LF-MPSD ablation for AF (PVI + diffuse PWI) between August 2017 and December 2019. Clinical characteristics were collected. Kaplan-Meier survival analysis was performed to study AF/atrial flutter (AFL) recurrence. Ablation data were analyzed in patients who underwent a repeat AF/AFL ablation. RESULTS: Of the 463 patients undergoing LF-MPSD AF ablation (PVI alone, or PVI + diffuse PWI), 137 patients had PVI + diffuse PWI. Acute PWI with complete electrocardiogram elimination was achieved in 134 (97.8%) patients. Among the 126 patients with consistent follow-up, 38 (30.2%) patients had AF/AFL recurrence during a median duration of 14 months. Eighteen patients underwent a repeat AF/AFL ablation after PVI + diffuse PWI, and 16 (88.9%) patients had durable PVI, in contrast to 10 of 45 (23.9%) patients who had redo ablation after LF-MPSD PVI alone. Seven patients (38.9%) had durable PWI, while 11 patients had partial electrical recovery at the posterior wall. The median percentage of area without electrical activity at the posterior wall was 70.7%. Conduction block across the posterior wall was maintained in 16 (88.9%) patients. CONCLUSION: There was a high rate of PVI durability in patients undergoing diffuse PWI and PVI. Partial posterior wall electrical recovery was common but conduction block across the posterior wall was maintained in most patients.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
15.
Mil Med ; 187(9): e1556-e1558, 2022 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-33851711

RESUMEN

Cholinergic urticaria is a common disorder that has been associated with anaphylaxis. We report the events, workup, and eventual second dose vaccination of a patient at the Walter Reed National Military Medical Center, who had immediate anaphylaxis after administration of the first Pfizer-BioNTech Covid-19 (BNT162b2) vaccine dose. During the initial evaluation after anaphylaxis, the patient described a history of symptoms suspicious for cholinergic urticaria but had never had this condition confirmed with standardized testing. After the episode of anaphylaxis, we performed several studies including immediate hypersensitivity skin testing, which did not demonstrate vaccine or component sensitization. We then performed an exercise provocation challenge and confirmed the diagnosis of cholinergic urticaria. These results, combined with the patient history, suggested that the episode of anaphylaxis was most likely driven by a severe flare of cholinergic urticaria. After obtaining the patient's consent, she received and tolerated her second dose without any objective findings of anaphylaxis. We conclude that patients with mast cell disorders or anaphylaxis after their first Covid-19 immunization will benefit from referral to an allergist since receipt of their second Covid-19 immunization may be possible.


Asunto(s)
Anafilaxia , Vacunas contra la COVID-19 , Urticaria , Femenino , Humanos , Anafilaxia/etiología , Anafilaxia/diagnóstico , Vacuna BNT162/efectos adversos , Colinérgicos , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Urticaria/complicaciones
16.
Retin Cases Brief Rep ; 16(1): 16-19, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31990820

RESUMEN

PURPOSE: To report a case of acute posterior multifocal placoid pigment epitheliopathy occurring in temporal association with multiple immunizations in a previously healthy 25-year-old woman. METHODS: Acute posterior multifocal placoid pigment epitheliopathy was diagnosed based on ophthalmological findings of bilateral placoid subretinal lesions complicated by a serous retinal detachment in the left eye. RESULTS: Through HLA typing, the patient was found to possess the HLA-B*40 and HLA-DB1*15 alleles. She was treated with topical prednisolone acetate 1% and monitored for several months. The serous retinal detachment resolved, and visual acuity returned to normal. CONCLUSION: This case report adds to the body of knowledge regarding possible atypical interplay between vaccines and specific T-cell receptors of the host immune system and adds Polio and Tetanus to the growing list of vaccines potentially triggering acute posterior multifocal placoid pigment epitheliopathy. Increased awareness of the presentation of acute posterior multifocal placoid pigment epitheliopathy and that it may arise after immunization may also improve evaluation of acute changes in visual acuity.


Asunto(s)
Vacunas , Síndromes de Puntos Blancos , Adulto , Femenino , Humanos , Vacunas/efectos adversos , Síndromes de Puntos Blancos/diagnóstico
17.
J Arrhythm ; 37(4): 1086-1092, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34386136

RESUMEN

OBJECTIVE: To assess the clinical and radiographic factors associated with lead failure by comparing subjects with lead failure within 10 years of implantation with an implant-year-matched group without lead failure. METHODS: A case-control study with 49 subjects who received Cardiac Implantable Electronic Device (CIED) between January 1, 1999 and July 31, 2008 and developed lead failure within 10 years of implantation in a single center. The control group consisted of subjects (n = 54) with normally functioning leads matched one-to-one by implant year. RESULTS: Among the failure group, the meantime from implantation to device lead failure was 4.70 ± 2.94 years. Older age at implantation was associated with a lower likelihood of lead failure (Odds Ratio (OR) = 0.28 (75 vs 42 years old), 95% CI 0.12-0.63, P = .002). A larger smallest loop diameter on the chest radiograph was also associated with a lower likelihood of lead failure (OR = 0.51 (31 vs 14 mm), 95% CI 0.27-0.97, P = .04). CIED type (defibrillator vs pacemaker) and Ottawa scores were not significantly associated with lead failure. Among lead-specific parameters, defibrillation lead vs pace-sense lead was associated with lead failure (OR = 3.91, 95% CI 1.95-7.81, P < .001). CONCLUSIONS: Younger age, defibrillation leads, and small lead loops are associated with lead failure in CIEDs. Techniques to avoid tight loops in the pocket could potentially reduce the risk of lead failure and bear important implications for the implanting physician.

18.
JACC Clin Electrophysiol ; 7(10): 1254-1263, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34217656

RESUMEN

OBJECTIVES: This study aimed to review the utility of quinidine in patients presenting with recurrent sustained ventricular arrhythmia (VA) and limited antiarrhythmic drug (AAD) options. BACKGROUND: Therapeutic options are often limited in patients with structural heart disease and recurrent VAs. Quinidine has an established role in rare arrhythmic syndromes, but its potential use in other difficult VAs has not been assessed in the present era. METHODS: We performed a retrospective analysis of 37 patients who had in-hospital quinidine initiation after multiple other therapies failed for VA suppression at our tertiary referral center. Clinical data and outcomes were obtained from the medical record. RESULTS: Of 30 patients with in-hospital quantifiable VA episodes, quinidine reduced acute VA from a median of 3 episodes (interquartile range [IQR]: 2 to 7.5) to 0 (IQR: 0 to 0.5) during medians of 3 days before and 4 days after quinidine initiation (p < 0.001). VA events decreased from a median of 10.5 episodes per day (IQR: 5 to 15) to 0.5 episodes (IQR: 0 to 4) after quinidine initiation in the 12 patients presenting with electrical storm (p = 0.004). Among the 24 patients discharged on quinidine, 13 (54.2%) had VA recurrence during a median of 138 days. Adverse effects in 9 of the 37 patients (24.3%) led to drug discontinuation, most commonly gastrointestinal intolerance. CONCLUSIONS: In patients with recurrent VAs and structural heart disease who have limited treatment options, quinidine can be useful, particularly as a short-term therapy.


Asunto(s)
Quinidina , Fibrilación Ventricular , Antiarrítmicos/uso terapéutico , Arritmias Cardíacas/tratamiento farmacológico , Humanos , Quinidina/uso terapéutico , Estudios Retrospectivos , Fibrilación Ventricular/tratamiento farmacológico
19.
JAMA Cardiol ; 6(10): 1202-1206, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34185045

RESUMEN

Importance: Myocarditis has been reported with COVID-19 but is not clearly recognized as a possible adverse event following COVID-19 vaccination. Objective: To describe myocarditis presenting after COVID-19 vaccination within the Military Health System. Design, Setting, and Participants: This retrospective case series studied patients within the US Military Health System who experienced myocarditis after COVID-19 vaccination between January and April 2021. Patients who sought care for chest pain following COVID-19 vaccination and were subsequently diagnosed with clinical myocarditis were included. Exposure: Receipt of a messenger RNA (mRNA) COVID-19 vaccine between January 1 and April 30, 2021. Main Outcomes and Measures: Clinical diagnosis of myocarditis after COVID-19 vaccination in the absence of other identified causes. Results: A total of 23 male patients (22 currently serving in the military and 1 retiree; median [range] age, 25 [20-51] years) presented with acute onset of marked chest pain within 4 days after receipt of an mRNA COVID-19 vaccine. All military members were previously healthy with a high level of fitness. Seven received the BNT162b2-mRNA vaccine and 16 received the mRNA-1273 vaccine. A total of 20 patients had symptom onset following the second dose of an appropriately spaced 2-dose series. All patients had significantly elevated cardiac troponin levels. Among 8 patients who underwent cardiac magnetic resonance imaging within the acute phase of illness, all had findings consistent with the clinical diagnosis of myocarditis. Additional testing did not identify other etiologies for myocarditis, including acute COVID-19 and other infections, ischemic injury, or underlying autoimmune conditions. All patients received brief supportive care and were recovered or recovering at the time of this report. The military administered more than 2.8 million doses of mRNA COVID-19 vaccine in this period. While the observed number of myocarditis cases was small, the number was higher than expected among male military members after a second vaccine dose. Conclusions and Relevance: In this case series, myocarditis occurred in previously healthy military patients with similar clinical presentations following receipt of an mRNA COVID-19 vaccine. Further surveillance and evaluation of this adverse event following immunization is warranted. Potential for rare vaccine-related adverse events must be considered in the context of the well-established risk of morbidity, including cardiac injury, following COVID-19 infection.


Asunto(s)
Vacunas contra la COVID-19/efectos adversos , COVID-19/prevención & control , Personal Militar/estadística & datos numéricos , Miocarditis/etiología , Vacunación/efectos adversos , Vacuna nCoV-2019 mRNA-1273 , Adulto , Vacuna BNT162 , COVID-19/diagnóstico , COVID-19/epidemiología , COVID-19/virología , Vacunas contra la COVID-19/administración & dosificación , Técnicas de Imagen Cardíaca/métodos , Dolor en el Pecho/etiología , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Servicios de Salud Militares/normas , Miocarditis/diagnóstico , Miocarditis/epidemiología , Estudios Retrospectivos , SARS-CoV-2/genética , Troponina/sangre , Estados Unidos/epidemiología , Vacunación/estadística & datos numéricos
20.
JACC Clin Electrophysiol ; 7(9): 1182-1192, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33812827

RESUMEN

OBJECTIVES: This study sought to investigate the factors associated with repeat infection following lead extraction procedures. BACKGROUND: Although lead extraction is an essential therapy for patients with cardiovascular implantable electronic device (CIED) infection, repeat infection still occurs in some patients. METHODS: The authors reviewed data for consecutive patients who underwent extraction of infected CIEDs from August 2003 to May 2019. Repeat infection was defined as infective endocarditis, sepsis with no alternative focus, or pocket infection after extraction of infected CIEDs. RESULTS: Extraction of infected CIEDs was performed in 496 patients. The most commonly implicated pathogen was Staphylococcus aureus (n = 188). In 449 patients (90.5%), all leads were completely extracted using only transvenous techniques. Thirty-three patients (6.7%) underwent surgical lead extraction, and 14 (2.8%) had retained leads or lead components. After a median follow-up of 352 [40 to 1,255] days after CIED extraction, 144 patients (29.0%) died. Repeat infection occurred in 47 patients (9.5%) with the median time from the extraction to repeat infection of 103 [45 to 214] days. In multivariable analysis, presence of a left ventricular assist device, younger age at extraction, and S. aureus infection were independent predictors of repeat infection. Additionally, chronic kidney disease, congestive heart failure, presence of septic emboli, S. aureus infection, and occurrence of major complications were independent predictors of increased mortality. CONCLUSIONS: Patients with S. aureus infection have a high risk of repeat infection and poor prognosis after CIED extraction. Repeat infection is also predicted by younger age and the presence of a left ventricular assist device, whereas mortality was predicted by congestive heart failure, chronic kidney disease, and septic emboli.


Asunto(s)
Desfibriladores Implantables , Infecciones Relacionadas con Prótesis , Desfibriladores Implantables/efectos adversos , Electrónica , Humanos , Infecciones Relacionadas con Prótesis/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Staphylococcus aureus
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...